Building overview:
The light steel structure hospital covering area is 1075 m2 (inside the outer wall), and the indoor net height is 3.0m (from the ground to the lowest part of the indoor roof panel).
Load fortification:
Wind load: 144 KM/H Snow load: 0.00 KN/m2
Roof dead load: 3.50 KN/m2 Roof live load: 2.50 KN/m2
Floor dead load: 3.50 KN/m2 Floor live load: 2.50 KN/m2
Material parameters:
Overall frame: The frame is a steel structure frame + light steel wall maintenance.
Floor maintenance: 1.0mm profiled steel plate + cast-in-place concrete (customers take care of themselves).
External wall maintenance: 15mm cement fiberboard external hanging board (including keel) + one-way breathing paper + 12mmOSB board (anti-termite) + 150mm glass insulation cotton + 12mmOSB board (anti-termite) + one-way breathing paper
+12mm gypsum board (replace 12mm gypsum board with 12mm cement fiber board inside the bathroom)
Internal wall maintenance: 12mm gypsum board + one-way breathing paper + 12mm OSB board (anti-termite) + 150mm glass insulation cotton + 12mm OSB board (anti-termite) + one-way breathing paper
+12mm gypsum board (replace the 12mm gypsum board inside the bathroom interior wall board with a single-layer 12mm cement fiber board)
Ceiling: 12mm gypsum board, 12mm moisture-proof gypsum board in the toilet area.